Influence of feldspar ceramic thickness on the properties of resin cements and restorative set
Fernanda Brombila Blumentritt1, Geórgia Cancian1, Júlia Machado Saporiti1
1Department of Restorative Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, Rio Grande do Sul, Brazil.
Abstract:
This in vitro study evaluated the influence of feldspathic ceramic thickness on the properties of light- and dual-cured resin cements. For each cement (RelyX Veneer, Allcem Veneer, RelyX Ultimate, and Allcem Dual), three ceramic specimens were prepared, with seven thicknesses for each (0.5, 1.0, 1.5, 2.0, 2.5, 3.0, and 3.5 mm). The degree of conversion, Vickers microhardness, irradiance power, color variation (ΔE00 ), and translucency parameters were assessed. Microhardness and irradiance power were analyzed using analysis of variance (ANOVA) with post hoc Tukey's test, while ΔE00 , translucency parameters, and degree of conversion were analyzed using ANOVA of ranks with post hoc Duncan's Multiple Range Test. The relationship between each of the dependent variables (degree of conversion, ΔE00 , and translucency parameter tests) and the specimen thickness was described using linear regression for each of the four resin cements. The significance level for all analyses was set at 5%. RelyX Ultimate yielded the lowest degree of conversion values among all resin cements. Allcem Veneer produced the lowest microhardness values, without statistical differences between thicknesses, of up to 1 mm. Allcem Dual produced the highest ΔE00 and translucency parameter values. Feldspathic ceramic thickness influenced the mechanical properties of resin cements and optical aspects of the restorative set.
Related Concept Videos
Setting Time of Cement
Porosity in Cement Paste
The balance of water to cement in the mix is...
Pore Size Distribution
Adequate...
Fineness of Cement
Direct...
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...