Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
Published on: December 20, 2016
Development and verification of a novel isotopic N2 O measurement technique for discrete static chamber samples using
Conor J Bracken1,2,3, Gary J Lanigan3, Karl G Richards3
1UCD School of Agriculture and Food Science, University College Dublin, Dublin, Ireland.
Rationale:
N2 O isotopomers are a useful tool to study soil N cycling processes. The reliability of such measurements requires a consistent set of international N2 O isotope reference materials to improve inter-laboratory and inter-instrument comparability and avoid reporting inaccurate results. All these are the more important given the role of N2 O in anthropogenic climate change and the pressing need to develop our understanding of soil N cycling and N2 O emission to mitigate such emissions. Cavity ring-down spectroscopy (CRDS) could potentially overcome resource requirements and technical challenges, making N2 O isotopomer measurements more feasible and less expensive than previous approaches (e.g., gas chromatography [GC] and isotope ratio mass spectrometry [IRMS]).
Methods:
A combined laser spectrometer and small sample isotope module (CRDS & SSIM) method enabled N2 O concentration, δ15 Nbulk , δ15 Nα , δ15 Nβ and site preference (SP) measurements of sample volumes <20 mL, such as static chamber samples. Sample dilution and isotopic mixing as well as N2 O concentration dependence were corrected numerically. A two-point calibration procedure normalised δ values to the international isotope-ratio scales. The CRDS & SSIM repeatability was determined using a reference gas (Ref Gas). CRDS & SSIM concentration measurements were compared with those obtained by GC, and the isotope ratio measurements from two different mass spectrometers were compared.
Results:
The repeatability (mean ± 1σ; n = 10) of the CRDS & SSIM measurements of the Ref Gas was 710.64 ppb (± 8.64), 2.82‰ (± 0.91), 5.41‰ (± 2.00), 0.23‰ (± 0.22) and 5.18‰ (± 2.18) for N2 O concentration, δ15 Nbulk , δ15 Nα , δ15 Nβ and SP, respectively. The CRDS & SSIM concentration measurements were strongly correlated with GC (r = 0.99), and they were more precise than those obtained using GC except when the N2 O concentrations exceeded the specified operating range. Normalising CRDS & SSIM δ values to the international isotope-ratio scales using isotopic N2 O standards (AK1 and Mix1) produced accurate results when the samples were bracketed within the range of the δ values of the standards. The CRDS & SSIM δ15 Nbulk and SP precision was approximately one order of magnitude less than the typical IRMS precision.
Conclusions:
CRDS & SSIM is a promising approach that enables N2 O concentrations and isotope ratios to be measured by CRDS for samples <20 mL. The CRDS & SSIM repeatability makes this approach suitable for N2 O "isotopomer mapping" to distinguish dominant source pathways, such as nitrification and denitrification, and requires less extensive lab resources than the traditionally used GC/IRMS. Current study limitations highlighted potential improvements for future users of this approach to consider, such as automation and physical removal of interfering trace gases before sample analysis.
More Related Videos
07:52A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
Related Concept Videos
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Atomization Methods
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
NMR Spectrometers: Resolution and Error Correction