Abstract:
The kinetic analyses are quite important when it comes to understanding the particle behavior in any device as they start to deviate from a continuum nature. In the present study, kinetic simulations are performed using the particle-in-cell method to analyze the behavior of ions inside a cylindrical inertial electrostatic confinement fusion (IECF) device which is being developed as a tabletop neutron source. Here, the lighter ions, like deuterium, are accelerated by applying an electrostatic field between the chamber wall (anode) and the cathode (cylindrical gridded wire), placed at the center of the device. The plasma potential profiles obtained from the simulated results indicate the formation of multiple potential well structures inside the cathode grid depending upon the applied cathode potential (from -1 to -5 kV). The ion density at the core region of the device is found to be of the order of 10^{16}m^{-3}, which closely resembles the experimental observations. Spatial variation of ion energy distribution function has been measured in order to observe the characteristics of ions at different cathode voltages. Finally, the simulated results are compared and found to be in good agreement with the experimental profiles. The present analysis can serve as a reference guide to optimize the technological parameters of the discharge process in IECF devices.
Related Concept Videos
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
The Energies of Atomic Orbitals
Motion Of A Charged Particle In A Magnetic Field
Coulomb's Law
Newton's third law applies to the Coulomb force — the...
Ionization Energy
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...