Related Experiment Video
Updated: Nov 20, 2025

11:57
Measuring Spatially- and Directionally-varying Light Scattering from Biological Material
Published on: May 20, 2013
13.8K
A Camera Intrinsic Matrix-Free Calibration Method for Laser Triangulation Sensor.
Xuzhan Chen1, Youping Chen1, Bing Chen1
1School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
Sensors (Basel, Switzerland)
|January 20, 2021
Summary
This study introduces a new method for calibrating laser triangulation sensors (LTS) without needing the camera intrinsic matrix. This approach simplifies recalibration and enhances displacement measurement precision in industrial applications.
Area of Science:
- Optics and Photonics
- Metrology and Measurement Science
- Robotics and Automation
Background:
- Laser triangulation sensors (LTS) are crucial for industrial depth acquisition.
- Unknown component parameters, particularly camera intrinsics, hinder recalibration of off-the-shelf LTS.
Purpose of the Study:
- To develop a novel, camera intrinsic matrix-free calibration method for LTS.
- To address the challenges of recalibrating degenerated LTS devices during maintenance.
Main Methods:
- Proposed a one-dimensional target-based calibration approach.
- Formulated LTS calibration as an optimization problem considering all sensor parameters simultaneously.
- Introduced a closed-form solution for target positioning to enable LTS parameter optimization.
Main Results:
- Successfully calibrated LTS without prior knowledge of the camera intrinsic matrix.
- Demonstrated significant improvement in displacement measurement precision post-calibration.
- Validated the method through simulations and experimental results.
Conclusions:
- The precise camera intrinsic matrix is not a prerequisite for accurate LTS displacement measurement.
- The proposed method offers a practical solution for recalibrating LTS in industrial settings.
- This technique enhances the reliability and accuracy of depth sensing technologies.
More Related Videos
Related Concept Videos
Glassware Calibration
1.0K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.0K
Instrument Calibration
511
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
511
Calibration Curves: Linear Least Squares
3.6K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
3.6K