Related Experiment Video
Updated: Nov 20, 2025

Combining Reflectance Confocal Microscopy with Optical Coherence Tomography for Noninvasive Diagnosis of Skin Cancers via Image Acquisition
Published on: August 18, 2022
Dynamic Spectral Imaging Colposcopy Versus Regular Colposcopy in Women Referred With High-Grade Cytology: A
Berit Bargum Booth, Lone Kjeld Petersen, Jan Blaakaer
1Department of Pathology, Randers Regional Hospital, Randers, Denmark.
Objective:
The aim of the study was to evaluate the sensitivity of dynamic spectral imaging (DSI) colposcopy compared with regular colposcopy for women referred with high-grade cervical cytology.
Methods:
In a prospective, nonrandomized, multicenter study, we included women referred for colposcopy at hospital gynecology clinics with high-grade cytology. Women were examined using either a regular or DSI colposcope. In both groups, colposcopists located 1 area viewed as most suspicious. In the DSI group, this was done before viewing the DSI map. Subsequently, an area was chosen based on the worst color of the DSI map, and further additional biopsies were taken. All women had 4 cervical biopsies taken, all analyzed separately. The main outcome was sensitivity to find cervical intraepithelial neoplasia grade 2 or worse (CIN2+).
Results:
A total of 261 women were examined using DSI colposcopy, and 156 women were examined using regular colposcopy. The sensitivity for finding CIN2+ when using the DSI technology as an adjunctive technology was found to be 82.2% (95% CI = 75.9-87.4), based on an average of 1.4 biopsies. This was corresponding in sensitivity to 2 biopsies taken using regular colposcopy (80.3%; 95% CI = 72.3-86.8). There was no difference in sensitivity for CIN+ between the groups when 3 or more biopsies were taken.
Conclusions:
We found that the DSI colposcope may help direct biopsy placement; however, the improvement is based on small differences in needed biopsies and the clinical significance of this may be small. Multiple biopsies were still superior.
More Related Videos
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...

