Three-dimensional tomographic assessment of the upper airway using 2 different imaging software programs: A
Michele Garcia-Usó1, Thiago F Lima1, Inge Elly K Trindade2
1Former Post-Graduation Student, Hospital for Rehabilitation of Craniofacial Anomalies, University of São Paulo, Bauru, São Paulo, Brazil.
Introduction:
Several imaging software programs with different tools are available for upper airway (UAW) analysis by means of cone beam computed tomography. Because of this wide variability, this study aimed to compare the reproducibility of two of the most used software programs on UAW segmentation, that is, Dolphin Imaging (Dolphin Imaging and Management Solutions, Chatsworth, Calif) and Mimics Research (Materialise, Leuven, Belgium).
Methods:
The sample consisted of 50 scans of adult subjects with Class III malocclusion; pharyngeal volume and minimal cross-sectional area (mCSA) were assessed twice by 2 experienced evaluators using both software programs. Intra- and intersoftware and/or evaluator agreement were calculated using the intraclass correlation coefficient (ICC). Bland-Altman analysis was used to visualize the intersoftware and interevaluator agreement.
Results:
Using Mimics Research and Dolphin Imaging, the respective mean values of volume (cm3) were 27.1 ± 8.4 and 24.7 ± 8.1 (P < 0.05) and of mCSA (mm2) were 167.8 ± 95.5 and 176.5 ± 102.3 (P < 0.05). Although differences between software packages were observed on both the analyzed variables, the results showed a high intersoftware agreement, with ICC of 0.87 (volume) and 0.97 (mCSA) and mean bias of 24.6 (volume) and -8.8 (mCSA). A high intrasoftware agreement was also observed, with values varying from 0.83 to 0.99. Excellent intra- and interevaluator agreement was also obtained, with ICC values from 0.93 to 0.99.
Conclusions:
Dolphin Imaging and Mimics Research individually provide highly reproducible results, with clinically acceptable agreement between them for UAW segmentation, providing consistent values for volume and mCSA.
More Related Videos
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...