Heart-rate agreement between ECG and a new, wireless device during early skin-to-skin contact
Related Experiment Video
Updated: Nov 20, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Anna Lavizzari1, Roberta Falgari1, Nicola Pesenti2
1Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Neonatal Intensive Care Unit, Milan, Italy.
Aim:
To assess the agreement of heart rate (HR) between the new device - a fabric jacket for neonates, with integrated sensors detecting ECG signals and a Bluetooth connection to a computer (ComfTech, HOWDY) - and the clinical reference, ECG, during the skin-to-skin contact (SSC) in the first 2 h after birth, for the potential use of early detection of Sudden and Unexpected Postnatal Collapse (SUPC).
Methods:
We enrolled newborns ≥35+0 weeks of gestation, with Apgar score >8 at 5 min in a prospective, observational study in the delivery room, excluding infants with need for resuscitation, clinical instability or major malformations. We assessed HR within 20 min after birth by both devices simultaneously: the index test ComfTech HOWDY and the standard ECG (Vita Guard VG 3100, Getemed). We compared HR between the two methods at 0, 15, 30, 45, 60, 90 and 120 min by the Bland-Altman plot.
Results:
We included 60 infants. The mean difference between the methods was -1.3 bpm, 95%LoA -12.4 to 9.7 bpm. Spearman rank correlation coefficient ρ = -0.06.
Conclusion:
ComfTech HOWDY presents reliable agreement with the ECG and might assist in identifying infants at risk for SUPC.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Holter Monitor: 24-Hour Monitoring
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...