Related Experiment Video
Updated: Nov 20, 2025

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
High flow nasal oxygen during procedural sedation for cardiac implantable electronic device procedures: A randomised
Aaron Conway1, Peter Collins, Kristina Chang
1From the Peter Munk Cardiac Centre, University Health Network (AC, PC, KC), Lawrence S. Bloomberg Faculty of Nursing, University of Toronto, Toronto, Ontario, Canada (AC, NK), School of Nursing, Queensland University of Technology (QUT), Brisbane, Queensland, Australia (AC), Department of Anesthesia and Pain Management, UHN (ALF, PL, MP), Department of Anesthesia and Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Ontario, Canada (MP).
Background:
High flow nasal oxygen may better support the vulnerable respiratory state of patients during procedural sedation.
Objective:
The objective of this study was to investigate the effects of high flow nasal oxygen in comparison to facemask oxygen on ventilation during cardiac implantable electronic device procedures performed with procedural sedation.
Design:
A randomised controlled trial.
Setting:
The study was conducted at one academic hospital in Canada.
Participants:
Adults undergoing elective cardiac implantable electronic device procedures with sedation administered by an anaesthesia assistant, supervised by an anaesthesiologist from August 2019 to March 2020.
Interventions:
Participants were randomised 1 : 1 to facemask (≥ 8 l · min-1) or high flow nasal oxygen (50 l · min-1 and a 50 : 50 oxygen to air ratio).
Main Outcome Measures:
The primary outcome was peak transcutaneous carbon dioxide. Outcomes were analysed using Bayesian statistics.
Results:
The 129 participants who were randomised and received sedation were included. The difference in peak transcutaneous carbon dioxide was 0.0 kPa (95% CI -0.17 to 0.18). Minor adverse sedation events were 6.4 times more likely to occur in the high flow nasal oxygen group. This estimate is imprecise (95% CI 1.34 to 42.99). The odds ratio for oxygen desaturation for the high flow nasal oxygen group compared with the facemask group was 1.2 (95% CI 0.37 to 3.75). The difference in satisfaction with sedation scores between groups was 0.0 (95% CI -0.33 to 0.23).
Conclusions:
Ventilation, as measured by TcCO2, is highly unlikely to differ by a clinically important amount between high flow nasal oxygen at 50 l min-1 or facemask oxygen at 8 l min-1. Further research with a larger sample size would be required to determine the optimal oxygen:air ratio when using high flow nasal oxygen during cardiac implantable electronic device procedures performed with sedation.
Trial Registration Number:
NCT03858257.
More Related Videos
05:43Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
07:54Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Suctioning the Nasopharyngeal Airway
Equipment Required