Optimal dual characteristics for enhancing coordination index in protecting forward and reverse fault currents
Sajjad Dadfar1, Majid Gandomkar1
1Department of Electrical Engineering, College of Electrical Engineering and Computer, Saveh Branch, Islamic Azad University, Saveh, Iran.
Abstract:
Satisfying coordination constraints among protective devices is a challenging task in the protection system of electrical grids. On the other hand, increasing interest on the distributed generations (DGs) jeopardizes the selectivity among overcurrent relays in active distribution networks. Therefore, sustainable electrification requires enhancing the protection coordination index (PCI) in order to increase DG penetration in these networks. In this paper, time-current-voltage characteristics and dual-setting directional overcurrent relays (DOCRs) are jointly employed to improve PCI in interconnected distribution networks. Dual-setting relays can operate in forward and reverse directions with individual settings in both directions which help to provide more flexibility in improving PCI. Moreover, the time-current-voltage characteristics have the voltage parameter in operation time of relays which can simplify the optimization process to yield higher flexibility in the coordination process. Furthermore, the proposed protection scheme is extended by user-defined time-current-voltage characteristics to improve PCI as much as possible. The proposed scheme is formulated as a nonlinear programming model that is solved by the genetic algorithm (GA). The proposed scheme is tested on IEEE 14-bus and 30-bus testbed. Results show a remarkable improvement.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
06:55Kinematic History of a Salient-recess Junction Explored through a Combined Approach of Field Data and Analog Sandbox Modeling
Published on: August 5, 2016
Related Concept Videos
Directional Relays
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Insulation Coordination
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Fault Types
For line-to-line faults occurring between phases B and C, the...