Preserved pressure delivery during high-frequency oscillation of bubble CPAP in a premature infant lung model with
Emidio M Sivieri1,2, David M Rub2,3, Soraya Abbasi1,2,3
1CHOP Newborn Care at Pennsylvania Hospital, Philadelphia, Pennsylvania, USA.
Background:
Bubble continuous positive airway pressure (BCPAP) generates pressure oscillations which are suggested to improve gas exchange through mechanisms similar to high frequency (HF) ventilation. In a previous in-vitro lung model with normal lung mechanics, significantly improved CO2 washout was demonstrated using an HF interrupter in the supply flow of a BCPAP system. The effect of HF with BCPAP on delivered airway pressure (Paw) has not been fully investigated in a lung model having abnormal pulmonary mechanics.
Objective:
To measure Paw in an infant lung model simulating normal and abnormal pulmonary compliance and resistance while connected to a BCPAP system with superimposed HF oscillations created using an in-line flow interrupter.
Design/Methods:
A premature infant lung model with either: normal lung mechanics, compliance 1.0 ml/cm H2 O, airway resistance 56 cm H2 O/(L/s); or abnormal mechanics, compliance 0.5 ml/cm H2 O, airway resistance 136 cm H2 O/(L/s), was connected to BCPAP with HF at either 4, 6, 8, 10, or 12 Hz. Paw was measured at BCPAPs of 4, 6, and 8 cm H2 O and respiratory rates (RR) of 40, 60, and 80 breaths/min and 6.0 ml tidal volume.
Results:
Mean Paw averaged over all five frequencies showed no significant change from non-oscillated levels at all BCPAPs and RRs for both lung models. Paw amplitudes (peak-to-trough) during oscillation were significantly greater than the non-oscillated levels by an average of 1.7 ± 0.5 SD and 2.6 ± 0.5 SD cm H2 O (p < .001) for the normal and abnormal models, respectively.
Conclusions:
HF oscillation of BCPAP using a flow interrupter did not alter mean delivered Paw compared to non-oscillated BCPAP for both normal and abnormal lung mechanics models. This simple modification to BCPAP may be a useful enhancement to this mode of non-invasive respiratory support.
Related Concept Videos
Pulmonary Cycle: Exhalation
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Mechanical Ventilation I: Indication and Settings