Related Experiment Video
Updated: Nov 19, 2025

A Machine Learning Approach to Design an Efficient Selective Screening of Mild Cognitive Impairment
Published on: January 11, 2020
Assessing the International Transferability of a Machine Learning Model for Detecting Medication Error in the General
Yen Po Harvey Chin1,2, Wenyu Song3, Chia En Lien4
1Department of Biomedical Informatics, Harvard Medical School, Boston, MA, United States.
Background:
Although most current medication error prevention systems are rule-based, these systems may result in alert fatigue because of poor accuracy. Previously, we had developed a machine learning (ML) model based on Taiwan's local databases (TLD) to address this issue. However, the international transferability of this model is unclear.
Objective:
This study examines the international transferability of a machine learning model for detecting medication errors and whether the federated learning approach could further improve the accuracy of the model.
Methods:
The study cohort included 667,572 outpatient prescriptions from 2 large US academic medical centers. Our ML model was applied to build the original model (O model), the local model (L model), and the hybrid model (H model). The O model was built using the data of 1.34 billion outpatient prescriptions from TLD. A validation set with 8.98% (60,000/667,572) of the prescriptions was first randomly sampled, and the remaining 91.02% (607,572/667,572) of the prescriptions served as the local training set for the L model. With a federated learning approach, the H model used the association values with a higher frequency of co-occurrence among the O and L models. A testing set with 600 prescriptions was classified as substantiated and unsubstantiated by 2 independent physician reviewers and was then used to assess model performance.
Results:
The interrater agreement was significant in terms of classifying prescriptions as substantiated and unsubstantiated (κ=0.91; 95% CI 0.88 to 0.95). With thresholds ranging from 0.5 to 1.5, the alert accuracy ranged from 75%-78% for the O model, 76%-78% for the L model, and 79%-85% for the H model.
Conclusions:
Our ML model has good international transferability among US hospital data. Using the federated learning approach with local hospital data could further improve the accuracy of the model.
More Related Videos
07:31Implementation of a Real-Time Psychosis Risk Detection and Alerting System Based on Electronic Health Records using CogStack
Published on: May 15, 2020
04:09Predicting Treatment Response to Image-Guided Therapies Using Machine Learning: An Example for Trans-Arterial Treatment of Hepatocellular Carcinoma
Published on: October 10, 2018
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Errors occurring during blood pressure monitoring
Several factors...