Related Experiment Video
Updated: Nov 19, 2025

Characterizing Electron Transport through Living Biofilms
Published on: June 1, 2018
Analysis of porous carbon biocathodes via three-dimensional impedance spectroscopy using a double channel
Isao Shitanda1, Hiromichi Inoue1, Yukihiro Yoshihata1
1Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan.
Abstract:
Porous carbon electrodes have considerably improved the performance of biofuel cells and biosensors in recent years. In this paper, we propose a novel in-situ analysis method for porous enzyme electrodes. By combining three-dimensional (3D) impedance measurement and a double-channel transmission line model, the stability of porous enzyme electrodes during operation can be evaluated. The proposed method can distinguish between the functional stability of the enzyme and mediator reaction and the general structural stability of the electrode. We demonstrated this method by evaluating bilirubin oxidase-modified carbon cloth (CC) electrodes with and without a magnesium oxide (MgO)-templated carbon coating. In case of the CC electrode, a remarkable increase in the charge transfer resistance within the first 500 s indicated the elution of the enzyme and mediator. When the CC was coated with MgO-templated carbon before enzyme modification, the charge transfer resistance remained constant, indicating an effective suppression of the elution of the enzyme and mediator. The electric double-layer capacitance values of both electrodes indicated that their general electrode structures were stable during the analysis. Thus, the proposed analytical method, based on 3D impedance, can be a powerful tool for simultaneously detecting possible changes in the general electrode structure of enzyme electrodes and in the amount of active enzymes and mediators on the electrode surface.
More Related Videos
10:23Characterizing Mediated Extracellular Electron Transfer in Lactic Acid Bacteria with a Three-Electrode, Two-Chamber Bioelectrochemical System
Published on: August 23, 2024
08:03Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research
Published on: April 18, 2013
Related Concept Videos
Bode Plots Construction
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...