Related Experiment Video
Updated: Nov 19, 2025

Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Design and analysis of magnetostrictive sensors for wireless temperature sensing
Manjunath C Rajagopal1, Sanjiv Sinha1
1Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA.
Abstract:
Magnetostrictive transducers are commonly used as actuators and sonar transducers, and in remote non-destructive evaluation. Their use in wireless thermometry is relatively unexplored. Since magnetostriction-based sensors are passive, they could potentially enable long-term near-field thermometry. While the temperature sensitivity of resonance frequency in magnetostrictive transducers has been reported in previous studies, the origin of the temperature sensitivity has, however, not been elucidated. Here, we identify material properties that determine temperature sensitivity and identify ways to improve sensitivity as well as the detection technique. Using a combination of analytical and computational methods, we systematically identify the material properties that directly influence the temperature coefficient of resonance frequency (TCF). We first experimentally measure the shift in resonance frequency due to temperature changes in a Metglas strip to be 0.03% K-1. Using insights from theory, we then experimentally demonstrate a fivefold improvement to the TCF by using Terfenol in place of Metglas as the magnetostrictive sensor material. We further demonstrate an alternate temperature sensing technique that does not require measuring the resonance frequency, consequently reducing instrument complexity. This work provides a general framework to analyze magnetostrictive materials and the sensing scheme for near-field wireless thermometry.
Related Concept Videos
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Design Example: Strain Gauge Bridge or Wheatstone Bridge
Magnetic Field Due to Two Straight Wires
Magnetic Field Due To A Thin Straight Wire
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...

