The 2020 "WHO Technical Specifications for Automated Non-Invasive Blood Pressure Measuring Devices With Cuff"
Oommen John1,2, Norm R C Campbell3, Tammy M Brady4
1From the George Institute for Global Health, University of New South Wales, New Delhi, India (O.J.).
Abstract:
High systolic blood pressure (BP) is the single leading modifiable risk factor for death worldwide. Accurate BP measurement is the cornerstone for screening, diagnosis, and management of hypertension. Inaccurate BP measurement is a leading patient safety challenge. A recent World Health Organization report has outlined the technical specifications for automated noninvasive clinical BP measurement with cuff. The report is applicable to ambulatory, home, and office devices used for clinical purposes. The report recommends that for routine clinical purposes, (1) automated devices be used, (2) an upper arm cuff be used, and (3) that only automated devices that have passed accepted international accuracy standards (eg, the International Organization for Standardization 81060-2; 2018 protocol) be used. Accurate measurement also depends on standardized patient preparation and measurement technique and a quiet, comfortable setting. The World Health Organization report provides steps for governments, manufacturers, health care providers, and their organizations that need to be taken to implement the report recommendations and to ensure accurate BP measurement for clinical purposes. Although, health and scientific organizations have had similar recommendations for many years, the World Health Organization as the leading governmental health organization globally provides a potentially synergistic nongovernment government opportunity to enhance the accuracy of clinical BP assessment.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure