Related Experiment Video
Updated: Nov 19, 2025

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Risk for Increased Mean Diastolic Gradient after Transcatheter Edge-to-Edge Mitral Valve Repair: A Quantitative
Didem Oguz1, Ratnasari Padang1, Nina Rashedi1
1Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota.
Background:
Iatrogenic mitral stenosis is a known limitation of transcatheter edge-to-edge mitral valve repair (TMVr), but determinants of increased postprocedural mean diastolic gradient (MG) are not well defined. The aim of this study was to determine correlates of increased post-TMVr MG or aborted clip implantation due to increased MG.
Methods:
Procedural three-dimensional transesophageal echocardiographic (TEE) data sets of 112 patients who underwent TMVr were retrospectively analyzed. Three-dimensional TEE mitral valve area (MVA) planimetry and mitral annular calcification (MAC) were quantified using multiplanar reconstruction. When MAC extension into the mitral leaflets was present, MAC with leaflet calcification (MAC-LC) length was recorded as the maximum distance from the mitral annulus to the most distal leaflet calcification. Increased MG after TMVr, measured on intraprocedural TEE imaging, was defined as ≥5 mm Hg or aborted clip implantation due to increased MG.
Results:
Baseline MVA was 5.9 ± 1.7 cm2, baseline MG was 2.1 ± 1.2 mm Hg, and MAC-LC length was 4.0 ± 4.5 mm. Thirty-two patients (29%) had increased post-TMVr MG. Risk for increased post-TMVr MG was 86%, 28%, and 14% in patients with baseline MVA < 4.0, 4.0 to 6.0, and >6.0 cm2, respectively (P < .001). In patients with baseline MVA 4.0 to 6.0 cm2, concurrent baseline MG ≥ 4 mm Hg or MAC-LC ≥ 6 mm was associated with higher risk for increased post-TMVr MG (53% vs 12%, P = .002). In patients with baseline MVA < 4.0 and >6.0 cm2, the risk for increased post-TMVr MG was similar in the presence or absence of baseline MG ≥ 4 mm Hg or MAC-LC ≥ 6 mm (P > .05 for both).
Conclusions:
Patients with baseline three-dimensional TEE MVA < 4.0 cm2 are at high risk for increased post-TMVr MG. Additionally, patients with borderline MVA (4.0-6.0 cm2) and concurrent MAC-LC length ≥ 6 mm or baseline MG ≥ 4 mm Hg are at moderate risk for increased MG after TMVr.
More Related Videos
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Mitral Regurgitation I: Introduction
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Stenosis I: Introduction
Mitral Regurgitation III: Medical Management
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis III: Medical Management