Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Accuracy of spectral curves at different phantom sizes and iodine concentrations using dual-source dual-energy
Kazuhiro Sato1, Ryota Kageyama2, Yuta Sawatani3
1Health Sciences, Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8575, Japan. satok@med.tohoku.ac.jp.
Abstract:
To validate the accuracy of spectral curves obtained by an image-data-based algorithm and clarify the error factors that reduce accuracy. Iodine rods of known composition and different concentrations were inserted into a cylinder or elliptic-cylinder phantom and scanned according to the dual-energy protocol. Spectral curves were obtained by (i) theoretical calculation, (ii) image-data-based 2-material decomposition, and (iii) using a dedicated workstation. Accuracy was verified by comparing the spectral curve obtained by theoretical calculations with those obtained by the image-data-based algorithms or the dedicated workstations. For a quantitative evaluation, the error and relative error (RE) were calculated. In the image-data-based calculation, the errors with respect to the theoretical CT number ranged from - 8.3 to 71.1 HU. For all 192 combinations, 80.7% of the errors were under ± 15 HU, and 97.9% of the REs were under 10%. In the dedicated workstation, the errors ranged from - 94.7 to 26.8 HU. For all combinations, 68.8% of the errors were under ± 15 HU, and 68.2% of the REs were under 10%. By appropriately setting the effective energy corresponding to the CT number of the basis materials, an accurate spectral curve can be obtained. The beam-hardening effect is canceled by the 2-material decomposition process even without beam-hardening correction. Accuracy is primarily reduced by scattered radiation rather than the beam-hardening effect.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation I: X-ray and CT