Customised weight-based volume contrast media protocol in CT of chest, abdomen and pelvis examination
Lilian Poh Poh Yap1, Jeannie Hsiu Ding Wong2, Nadia Fareeda Muhammad Gowdh3
1Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur, Malaysia; Department of Biomedical Imaging, University of Malaya Medical Centre, Lembah Pantai, 59100 Kuala Lumpur, Malaysia; Research Unit of Biomedical Imaging, University of Malaya Medical Centre, Lembah Pantai, 59100 Kuala Lumpur, Malaysia.
Introduction:
Fixed volume (FV) contrast media administration during CT examination is the standard practice in most healthcare institutions. We aim to validate a customised weight-based volume (WBV) method and compare it to the conventional FV methods, introduced in a regional setting.
Methods:
220 patients underwent CT of the chest, abdomen and pelvis (CAP) using a standard FV protocol, and subsequently, a customised 1.0 mL/kg WBV protocol within one year. Both image sets were assessed for contrast enhancement using CT attenuation at selected regions-of-interest (ROIs). The visual image quality was evaluated by three radiologists using a 4-point Likert scale. Quantitative CT attenuation was correlated with the visual quality assessment to determine the HU's enhancement indicative of the image quality grades. Contrast media usage was calculated to estimate cost-savings from both protocols.
Results:
Mean patient age was 61 ± 14 years, and weight was 56.1 ± 8.7 kg. FV protocol produced higher contrast enhancement than WBV, p < 0.001. CT images' overall contrast enhancement was negatively correlated with body weight for FV protocol while the WBV protocol produced more consistent enhancement across different body weight. More than 90% of the images from both protocols were graded "Excellent". WBV protocol also enabled a 28% cost reduction with cost savings of US$1238.
Conclusion:
The customised WBV protocol produced CT images which were comparable to FV protocol for CT CAP examinations. A median CT value of 100 HU can be an indicator of good image quality for the WBV protocol.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...