Related Experiment Video
Updated: Nov 19, 2025

Image Acquisition using Portable Sonography for Emergency Airway Management
Published on: September 28, 2022
CT imaging of extraglottic airway device-pictorial review
Tatsuya Norii1, Yohsuke Makino2, Kana Unuma3
1Department of Emergency Medicine, University of New Mexico Health Sciences Center, MSC11 6025 Lomas Blvd NE, Albuquerque, NM, 87131-0001, USA. TaNorii@salud.unm.edu.
Abstract:
Compared to intubation with a cuffed endotracheal tube, extraglottic airway devices (EGDs), such as laryngeal mask airways, are considered less definitive ventilation conduit devices and are therefore often exchanged via endotracheal intubation (ETI) prior to obtaining CT images. With more widespread use and growing comfort among providers, reports have now described use of EGDs for up to 24 h including cases for which clinicians obtained CT scans with an EGD in situ. The term EGD encompasses a wide variety of devices with more complex structure and CT appearance compared to ETI. All EGDs are typically placed without direct visualization and require less training and time for insertion compared to ETI. While blind insertion generally results in functional positioning, numerous studies have reported misplacements of EGDs identified by CT in the emergency department or post-mortem. A CT-based classification system has recently been suggested to categorize these misplacements in six dimensions: depth, size, rotation, device kinking, mechanical blockage of the ventilation opening(s), and injury from EGD placement. Identifying the type of EGD and its correct placement is critically important both to provide prompt feedback to clinicians and prevent inappropriate medicolegal problems. In this review, we introduce the main types of EGDs, demonstrate their appearance on CT images, and describe examples of misplacements.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Cardiopulmonary Resuscitation II: ACLS Airway Management
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...

