Related Experiment Video
Updated: Nov 18, 2025

Effects of Surgical Masks on Cardiopulmonary Function in Healthy Subjects
Published on: February 12, 2021
Effects of Wearing the Elevation Training Mask During Low-intensity Cycling Exercise on Intraocular Pressure
Jesús Vera1, Raimundo Jiménez1, Beatríz Redondo1
1Department of Optics, Faculty of Sciences.
Prcis:
Low-intensity aerobic exercise is recommended to reduce intraocular pressure (IOP) levels. However, this effect depends on several factors. We found that using an elevation training mask (ETM) during low-intensity aerobic exercise causes an IOP rise.
Purpose:
The aim was to assess the influence of wearing an ETM on IOP during low-intensity endurance training.
Methods:
Sixteen physically active young adults (age=23.9±2.9 y) cycled during 30 minutes at 10% of maximal power production with and without an ETM in 2 different days and randomized order. A rebound tonometer was used to measure IOP at baseline, after a warm-up of 5 minutes, during cycling (6, 12, 18, 24, and 30 min), and recovery (5 and 10 min) by rebound tonometry.
Results:
The use of an ETM significantly affects the IOP behaviour during exercise (P<0.001, ηp²=0.66). In the ETM condition, there was an IOP increment during exercise (P<0.001, ηp²=0.28) whereas an IOP-lowering effect was observed in the control condition (P<0.001, ηp²=0.41). Post hoc comparisons showed that there were greater IOP values during exercise in the ETM condition in comparison to the control condition (average IOP difference=3.7±2.2 mm Hg; corrected P<0.01, and the Cohen d's >1.10, in all cases).
Conclusion:
Low-intensity endurance exercise causes an increment in IOP when it is performed wearing an ETM and a decrease in IOP when the air flow is not restricted (control condition). Therefore, the ETM should be discouraged during low-intensity endurance exercise for individuals who need to reduce IOP levels (eg, glaucoma patients or those at risk). However, the external validity of these results needs to be addressed in future studies with the inclusion of glaucoma patients.
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...