Related Experiment Video
Updated: Nov 18, 2025

Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
LICAR: An Application for Isotopic Correction of Targeted Lipidomic Data Acquired with Class-Based Chromatographic
Liang Gao1,2, Shanshan Ji2, Bo Burla2
1Department of Biochemistry, Yong Loo Lin School of Medicine, National University of Singapore, 28 Medical Drive #03-03, 117456 Singapore.
Accurate lipid quantification in biomedical research requires correcting for isotopic overlap in multiple reaction monitoring (MRM) analyses. This study introduces an R algorithm for precise isotopic correction in lipidomics, improving data reliability for clinical applications.
Area of Science:
- Biomedical research
- Clinical research
- Analytical chemistry
Background:
- Lipidomics requires precise lipid quantification for clinical translation.
- Class-based chromatographic separation (HILIC, NPLC, SFC) in lipidomics causes isotopic overlap.
- Existing isotopic correction methods are unsuitable for multiple reaction monitoring (MRM) analyses.
Purpose of the Study:
- To develop and validate an algorithm for accurate isotopic correction in lipidomics using MRM.
- To address the limitations of current isotopic correction methods in MRM analyses with class-based separation.
- To improve the reliability of lipid quantification in clinical lipidomics.
Main Methods:
- Development of an R-based algorithm for isotopic correction using structural information from MRM transitions.
- Validation using analytical standards to assess the accuracy of isotopic contribution estimation.
- Application to human plasma samples to demonstrate the impact on lipid quantitation.
Main Results:
- The algorithm accurately estimates the isotopic contribution of isotopologues to MRM transition intensities.
- Over one-third of phosphatidylcholine species in human plasma required >10% intensity correction.
- Demonstrated the necessity of adequate isotopic correction for accurate lipid quantitation in MRM-based lipidomics.
Conclusions:
- The developed algorithm and R package provide accurate isotopic correction for lipidomics using MRM with class-based separation.
- This method enhances the precision of lipid quantification, crucial for clinical translation.