Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
Analytical performance of Raman spectroscopy in assaying biochemical components in human serum
Stella Giansante1, Hector Enrique Giana2, Adriana Barrinha Fernandes1
1Center for Innovation, Technology and Education - CITÉ, Universidade Anhembi Morumbi - UAM, Parque Tecnológico de São José dos Campos, Estr. Dr. Altino Bondensan, 500, São José dos Campos, SP, 12247-016, Brazil.
Abstract:
Chronic non-infectious diseases are important to research as they are the main causes of death in Brazil and worldwide. One very important chronic non-infectious disease is cardiovascular disease, whose risk factors (diabetes, dyslipidemia, and renal failure) can be detected through assessments of serum biochemical components. The objective of this study was to evaluate the analytical performance of Raman spectroscopy for analysis of lipid profile (total cholesterol, triglycerides, and HDL cholesterol), non-protein nitrogenous compounds (urea and creatinine), and glucose in 242 human serum samples. Models to discriminate and quantify the samples were developed using the predicted concentration by quantitative regression model based on partial least squares (PLS). The analytical error for the "leave-one-out" cross-validation based on the predicted PLS concentration was 10.5 mg/dL for total cholesterol, 21.4 mg/dL for triglyceride, 13.0 mg/dL for HDL cholesterol, 4.9 mg/dL for urea, 0.21 mg/dL for creatinine, and 15.4 mg/dL for glucose. The Kappa coefficient indicate very good agreement for cholesterol (0.83), good for triglyceride (0.77), urea (0.70) and creatinine (0.66), and fair for HDL cholesterol (0.38) and glucose (0.30). The results of the analytical performance demonstrated that Raman spectroscopy can be considered an important methodology to screen the population, especially for serum triglycerides and cholesterol.
More Related Videos
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...