Related Experiment Video
Updated: Nov 18, 2025

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Health Preference Measures in Patients with Obstructive Sleep Apnea Syndrome Undergoing Continuous Positive Airway
Fabienne L Huber1, Michael Furian1, Malcolm Kohler1
1Department of Respiratory Medicine, Sleep Disorders Center, University Hospital Zurich, Zurich, Switzerland.
Background:
In patients with obstructive sleep apnea syndrome (OSAS), the preference-based, health-related quality of life in terms of utility has not been extensively studied.
Objective:
To address this point, we compared the performance of different instruments assessing utility in patients with OSAS undergoing continuous positive airway pressure (CPAP) therapy.
Materials And Methods:
Data of 208 patients with OSAS (28 women, mean ± SE age 54.4 ± 0.7 years, apnea-hypopnea index (AHI) 51.9 ± 1.8/h, Epworth sleepiness score 13.4 ± 0.2) participating in a randomized trial of different CPAP modalities over 2 years were analyzed. Evaluations included sleep studies, Epworth sleepiness scale, and several utility instruments that measure subjective health preference on a scale ranging from 1 (most preferred and perfect health) to 0 (least preferred and very poor health).
Results:
After 2 years of CPAP therapy, the mean ± SE AHI was 6.7 ± 1.5/h and Epworth score 7.9 ± 0.4, both p < 0.001 versus baseline. Baseline utilities and changes (95% confidence interval) after 2 years of CPAP therapy were EuroQol 5-dimensions 0.79 ± 0.01, 0.02 (0.00-0.05, p = 0.064); short-form 6-dimension medical outcome questionnaire 0.72 ± 0.01, 0.06 (0.04-0.08, p < 0.001); Euro-thermometer visual analog scale 0.70 ± 0.01, 0.09 (0.07-0.12, p < 0.001); time trade-off 0.82 ± 0.01, 0.03 (0.01-0.06, p = 0.002); and standard gamble 0.82 ± 0.01, -0.01 (-0.03 to 0.02, p = 0.712).
Conclusion:
The short-form 6-dimensions questionnaire, the Euro-thermometer, and the time trade-off instruments reflected the major clinical improvements in OSAS, while the EuroQoL 5-dimensions and standard gamble tests were not sensitive to CPAP effects. These results indicate that the evaluation of utility of a treatment for OSAS depends critically on the instrument used, which is important from an individual and societal perspective.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Heart Failure VI: Adjunct Therapies
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Cardiopulmonary Resuscitation II: ACLS Airway Management

