Maintaining reduction during fixation of complex intra-articular distal radius fractures with dorsal comminution can be challenging. We describe an operative technique where reduction is achieved with temporary intrafocal Kirschner wires (K-wires), and held using surgical adhesive tape wrapped around the hand, whilst a volar plate is applied to achieve rigid fixation. This is a simple, inexpensive method used at our institutions which allows fixation of these fractures without the need for an operative assistant.