Related Experiment Video
Updated: Nov 18, 2025

Author Spotlight: Hickman Catheter Use for Long-Term Vascular Access in a Preclinical Swine Model
Published on: March 31, 2023
Repair of central venous access devices in intestinal failure patients is safe and cost-effective: A retrospective
Jane Fletcher1, Diane Woodham1, Sheldon C Cooper1
1Queen Elizabeth Hospital Birmingham, University Hospitals Birmingham NHS Foundation Trust, Edgbaston, Birmingham B15 2GW, UK.
Introduction:
Patients with chronic intestinal failure (IF) require home parenteral nutrition (HPN). Central venous access is needed for prolonged use of PN, usually via a long term central venous access device (CVAD). Post insertion there may be mechanical complications with a CVAD such as catheter rupture or tear. Repair of damaged CVADs is possible to avoid risks associated with catheter replacement in patients with IF. However, catheter related blood stream infections (CRBSI) are a concern when CVAD's are accessed or manipulated.
Aims:
To investigate the success of repair of CVADs in patients with IF on HPN, related to repair longevity and incidence of CRBSI following repair.
Method:
Nutrition team records of CVAD repairs carried out in patients with IF were reviewed retrospectively for the period April 2015 to March 2019.
Results:
Nutrition Clinical Nurse Specialists carried out 38 repairs in 27 patients. Male n = 5, female n = 22; mean age 55 years. Catheter longevity before first repair (n = 27): median 851 days, IQR 137-1484 days. 30/38 (78.9%) of repairs were successful lasting ≥30days. Hospital admission was avoided in 76% of cases. 4 patients in the failed repair group underwent catheter re-insertion where 4 had a further, subsequently successful, repair, an overall success rate of 89.4% (34/38). 30-day CRBSI rate was 0.09/1000 catheter days in repaired catheters. In comparing costs, there is a potential cost saving of 2766GBP for repair compared to replacement of damaged CVADs.
Conclusion:
Repair of tunnelled CVADs in patients with IF is successful and safe with no increased risk of CRBSI. Significant cost savings may be made.
More Related Videos
09:17Use of a Central Venous Line for Fluids, Drugs and Nutrient Administration in a Mouse Model of Critical Illness
Published on: May 2, 2017
09:57A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Related Concept Videos
Hemodialysis II: Procedure and Complications
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Varicose Veins II: Diagnostic Studies and Interprofessional Care