Related Experiment Video
Updated: Nov 18, 2025

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Comparison of Sampling Methods for International Normalized Ratio Monitoring in Haemodialysis Patients (INRHaemo
Theepika Rajkumar1, Jeffrey Wong2, Michael Harvey3
1Department of Medicine, Campbelltown Hospital, Campbelltown, New South Wales, Australia, theepika.rajkumar@gmail.com.
Background:
Haemorrhagic and thrombotic complications are common in dialysis patients on warfarin; thus, accurate international normalized ratio (INR) monitoring is critical. For expediency and patient comfort, blood sampling from the haemodialysis access or circuit is commonly performed. Point-of-care (POC) INR machines allow both peripheral vein preservation and rapid results, yet are not validated in the haemodialysis population.
Methods:
A prospective cohort study in haemodialysis patients taking warfarin was undertaken. Three paired samples were drawn over a single session: peripheral blood INR, POC INR, and dialysis INR. Agreement using Bland-Altman analysis and correlation coefficients between the peripheral blood INR, haemodialysis INR, and POC INR were calculated. Inappropriate dosing decisions based on haemodialysis or POC INR were quantified.
Results:
Amongst 34 patients, agreement between the dialysis INR and peripheral blood INR was high, with the haemodialysis INR differing from the peripheral INR by <±0.2, 85.2% of the time. Correlation between the 2 methods was high (r = 0.914; p < 0.001). POC INR differed from peripheral INR values by <±0.2, 67.6% of the time, with less agreement at higher INR values. Dosing decisions were incongruent between the dialysis and peripheral INR in 6%, whilst the POC and peripheral INR disagreed in 26%.
Conclusions:
There was good agreement and correlation between the peripheral blood, haemodialysis access/circuit, and POC INR values. POC INR was less reliable at higher values, and dosing decisions differed from the peripheral INR in a quarter of cases.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
04:52Dynamic Continuous Blood Extraction from Rat Heart via Noninvasive Microdialysis Technique
Published on: September 13, 2022
Related Concept Videos
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Hemodialysis III: Nursing Management
Continuous Renal Replacement Therapy
Hemodialysis I: Introduction
Hemodialysis II: Procedure and Complications