Related Experiment Video
Updated: Nov 18, 2025

08:34
Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
11.9K
Noncontact Respiratory Monitoring Using Depth Sensing Cameras: A Review of Current Literature
Anthony P Addison1, Paul S Addison1, Philip Smit1
1Medtronic, Video Biosignals Group, Patient Monitoring, Edinburgh EH26 0PJ, UK.
Sensors (Basel, Switzerland)
|February 10, 2021
Summary
Depth sensing cameras offer noncontact respiratory monitoring, providing waveforms, rates, and volumes. This technology enables reduced patient restriction and disease spread, with potential for clinically useful data.
Area of Science:
- Biomedical Engineering
- Medical Technology
- Respiratory Physiology
Background:
- Noncontact patient monitoring is crucial for reducing patient restriction and healthcare-associated infections.
- Traditional monitoring methods can be invasive or require disposable supplies.
- Emerging technologies are needed for remote and continuous patient assessment.
Purpose of the Study:
- To review the capabilities of depth sensing camera systems for noncontact respiratory monitoring.
- To evaluate the accuracy and clinical utility of this technology for respiratory surveillance.
- To explore the potential applications in assessing respiratory patterns and events.
Main Methods:
- Review of existing literature and technologies utilizing depth sensing cameras for respiratory monitoring.
- Analysis of data derived from depth sensing systems, including respiratory waveforms and derived parameters.
- Assessment of the correlation between camera-based measurements and established clinical metrics.
Main Results:
- Depth sensing cameras can generate detailed respiratory waveforms.
- Accurate calculation of respiratory rate and tidal volume is achievable.
- Detection of respiratory patterns and apneas is feasible with this technology.
Conclusions:
- Depth sensing camera systems show significant promise for noncontact respiratory monitoring.
- The technology offers a viable alternative to traditional methods, enhancing patient comfort and safety.
- Further validation is warranted to establish its widespread clinical adoption.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
2.0K
Respiratory Depth
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
2.0K
Assessment of Ventilation I: Respiratory Rate
1.6K
Assessment of Ventilation
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
1.6K

