Related Experiment Video
Updated: Nov 17, 2025

Interactive and Visualized Online Experimentation System for Engineering Education and Research
Published on: November 24, 2021
On Systematic Design of Fractional-Order Element Series
Jaroslav Koton1, David Kubanek1, Jan Dvorak1
1Department of Telecommunications, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, 616 00 Brno, Czech Republic.
Abstract:
In this paper a concept for the efficient design of a series of floating fractional-order elements (FOEs) is proposed. Using even single or a very limited number of so-called "seed" FOEs it is possible to obtain a wide set of new FOEs featuring fractional order α being in the range [-n,n], where n is an arbitrary integer number, and hence enables to overcome the lack of commercial unavailability of FOEs. The systematic design stems from the utilization of a general immittance converter (GIC), whereas the concept is further developed by proposing a general circuit structure of the GIC that employs operational transconductance amplifiers (OTAs) as active elements. To show the efficiency of the presented approach, the use of only up to two "seed" FOEs with a properly selected fractional order αseed as passive elements results in the design of a series of 51 FOEs with different α being in the range [-2,2] that may find their utilization in sensor applications and the design of analog signal processing blocks. Comprehensive analysis of the proposed GIC is given, whereas the effect of parasitic properties of the assumed active elements is determined and the optimization process described to improve the overall performance of the GIC. Using OTAs designed in 0.18 μμm TSMC CMOS technology, Cadence Virtuoso post-layout simulation results of the GIC are presented that prove its operability, performance optimization, and robustness of the proposed design concept.
More Related Videos
Related Concept Videos
First Order Systems
When a first-order system is subjected to a unit-step input, its response is characterized by its transfer function. By applying the Laplace transform of the unit-step input to the transfer function, expanding the...
Second Order systems II
Sequences
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
Partial Fractions
Second Order systems I
By reinterpreting the system, one can derive the closed-loop transfer function, which...

