Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

493
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
493
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

819
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
819
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

1.3K
Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
1.3K
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

1.3K
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
1.3K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

1.0K
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
1.0K
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

1.7K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
1.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Differences in Reported Anaphylaxis Associated With Common Nonsteroidal Anti-inflammatory Drugs: A Pharmacovigilance Study.

International archives of allergy and immunology·2026
Same author

Microfluidic self-assembled polysaccharide@zein-curcumin ternary nanoparticles: Polysaccharide structure, functional properties and stabilization mechanisms.

Food chemistry·2026
Same author

Functional brain alterations associated with acupuncture for chronic pain: a scoping review of fMRI studies.

Frontiers in neuroscience·2026
Same author

Spatiotemporally programmed nanomedicine engineering to resolve conflicting immunosignals in triple-negative breast cancer.

Signal transduction and targeted therapy·2026
Same author

Dynamic central-peripheral balance in brain-muscle interactions reveals motor impairment in post-stroke hemiplegia: an exploratory study.

Cognitive neurodynamics·2026
Same author

Energy-Based Multiresolution Analysis of FBG-Measured Strain Responses for Void Detection in Curved Pressure Vessel Structures Under Guided Wave Excitation.

Sensors (Basel, Switzerland)·2026

Related Experiment Video

Updated: Nov 17, 2025

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
10:42

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing

Published on: March 22, 2019

6.4K

Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method.

Haoyang Yu1, Qian Zhou1, Xinghui Li1

  • 1Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China.

Sensors (Basel, Switzerland)
|February 12, 2021
PubMed
Summary

A new post-processing method simplifies dual-comb spectroscopy for gas detection. This technique enhances spectral resolution and accuracy, making advanced spectroscopy more accessible for field applications.

Keywords:
dual-comb spectroscopyerror correctiongas detectionmolecular absorption spectroscopynoise suppression

More Related Videos

High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy
10:40

High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy

Published on: June 28, 2016

7.8K
Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
09:46

Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging

Published on: April 28, 2022

4.4K

Related Experiment Videos

Last Updated: Nov 17, 2025

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
10:42

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing

Published on: March 22, 2019

6.4K
High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy
10:40

High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy

Published on: June 28, 2016

7.8K
Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
09:46

Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging

Published on: April 28, 2022

4.4K

Area of Science:

  • Spectroscopy
  • Gas Detection
  • Physical Chemistry

Background:

  • Dual-comb spectroscopy offers high resolution, sensitivity, and speed for gas analysis.
  • Current limitations include complexity and high cost for field deployment.

Discussion:

  • A novel frequency domain post-processing method is proposed to simplify dual-comb spectroscopy.
  • This method extracts accurate absorption line positions frame-by-frame for enhanced analysis.
  • It achieves high accuracy with a residual error standard deviation of ~0.002.

Key Insights:

  • The method significantly improves spectral resolution from 13.4 GHz to 4.3 GHz.
  • It enables acquisition of H¹³C¹⁴N gas absorbance spectra over a 1.1 THz range.
  • Achieves results comparable to conventional correction methods.

Outlook:

  • This cost-effective approach eliminates the need for specialized equipment and complex algorithms.
  • It paves the way for wider adoption of Doppler-limited spectroscopy in field applications.
  • Potential for broader applications in environmental monitoring and industrial process control.