Heating stability, physical and chemical analysis of calcium silicate-based endodontic sealers
T B M Antunes1, A C P Janini1, L E Pelepenko1
1Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil.
Aim:
To evaluate possible modifications in root canal sealers subjected to a variety of heating conditions using vibrational spectroscopy and analysis of physical and chemical properties.
Methodology:
EndoSequence BC Sealer HiFlow, Bio-C Sealer, BioRoot RCS and AH Plus were analysed chemically using Raman spectroscopy (25-220 °C) and Fourier-transform infrared spectroscopy (FT-IR) (37-100 °C ). For FT-IR, the materials were tested individually and mixed with root dentine powder. Scanning electron microscopy (SEM) and coupled energy dispersive spectroscopy (EDS) were used to evaluate surface and chemical elements. ISO 6876-2012 and ASTM-C266-07 specifications were followed to evaluate flow, setting time (moist and dry), solubility and radiopacity. Also, pH analysis at 37 and 100 °C was performed. Shapiro-Wilk and Mixed ANOVA (within and between the effects of the subjects), Levene, and a post hoc analyses with Bonferroni correction were performed (P < 0.05).
Results:
Vibrational spectroscopy revealed peaks of tricalcium silicate, dicalcium silicate and zirconium dioxide. Chemical changes in the Raman spectra during heating were discrete, as the inorganic content predominated the signalling for all root canal sealers. FT-IR analysis exhibited spectral changes in water absorption for EndoSequence BC Sealer HiFlow and Bio-C Sealer, probably related to dehydration. For BioRoot RCS and AH Plus, no significant chemical changes were observed. Bio-C Sealer exhibited a band of polyethylene glycol only after heating to 100 °C, probably related to its thermal decomposition. SEM/EDS analysis corroborated the composition results observed in vibrational spectroscopy for all materials. Heating to 100 °C significantly changed the flowability of all calcium silicate-based sealers with a wide variation in setting times at both temperatures, along with solubility levels above ISO standards. For all tested sealers, radiopacity fulfilled the requirements, and pH exhibited alkaline values.
Conclusions:
The tested calcium silicate-based sealers were affected by heating. Calcium silicate-based root canal sealers had high solubility which is a concern for their clinical use. AH Plus was the only root canal sealer that was stable after heating.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Related Concept Videos
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Hydration of Cement
Soundness of Cement
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Mortar Properties