Nipple units for newborn infants: a functional comparison.

O P Mathew1

  • 1Department of Pediatrics, University of Texas Medical Branch, Galveston 77550.

Pediatrics
|May 1, 1988
PubMed
Summary

Nipple flow rates vary significantly between brands and types, impacting infant feeding. Understanding these differences in milk flow is crucial for neonatal care and selecting appropriate feeding equipment.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Spectrum of Haemoglobinopathies in a Tertiary Care Hospital of Armed Forces.

Medical journal, Armed Forces India·2016
Same author

Impact of Body Mass Index on Left Ventricular Function.

Medical journal, Armed Forces India·2016
Same author

Apnea of prematurity: pathogenesis and management strategies.

Journal of perinatology : official journal of the California Perinatal Association·2010
Same author

A case of hereditary protein S deficiency presenting with cerebral sinus venous thrombosis and deep vein thrombosis at high altitude.

Acta haematologica·2008
Same author

WPW and preexcitation syndromes.

The Journal of the Association of Physicians of India·2008
Same author

Non-sinus bradyarrhythmias in very low birth weight infants.

Journal of perinatology : official journal of the California Perinatal Association·2006

Area of Science:

  • Neonatal care
  • Biomedical engineering
  • Pediatric nutrition

Background:

  • Nipple flow characteristics are critical for successful infant feeding.
  • Variability in nipple flow can affect formula intake and infant comfort.
  • Standardized testing is needed to compare different nipple units.

Purpose of the Study:

  • To compare the milk flow characteristics of various nipple units used in neonatal feeding.
  • To determine the impact of negative pressure on flow rates for different nipple types.
  • To identify nipples with optimal flow for term and preterm infants.

Main Methods:

  • A mechanical system simulated infant sucking to measure flow rates.
  • The time to empty 120 mL of formula was recorded for each nipple unit.
  • Different negative pressures (-60 to -120 cm H2O) were applied.

Main Results:

  • Flow rates generally increased with higher negative pressure, except for SMA premature infant nipples.
  • Nuk-type nipples exhibited higher flow (fewer sucks) than standard types.
  • Significant variability in flow was observed both between and within nipple unit types.

Conclusions:

  • Nipple unit performance varies widely, necessitating careful selection for individual infants.
  • Differences in flow characteristics may have clinical relevance for neonatal feeding.
  • Further research is needed to optimize nipple design for diverse neonatal needs.