Prediction of Phakic Intraocular Lens Vault Using Machine Learning of Anterior Segment Optical Coherence Tomography
Kazutaka Kamiya1, Ik Hee Ryu2, Tae Keun Yoo3
1From Visual Physiology, School of Allied Health Sciences.
Purpose:
To compare the achieved vault using the conventional manufacturer's nomogram and the predicted vault using machine learning, in a large cohort of eyes undergoing posterior chamber phakic intraocular lens (EVO implantable collamer lens [ICL]; STAAR Surgical) implantation.
Design:
Reliability and validity assessment and comparison.
Methods:
Our study comprised a total of 1,745 eyes of 1,745 consecutive patients (mean age ± standard deviation, 26.2 ± 6.8 years) undergoing ICL implantation. At 1 month postoperatively, we quantitatively measured the actual vault, and compared it with the predicted vault using machine leaning of anterior segment optical coherence tomography metrics.
Results:
All machine learning methods, such as support vector regressor (SVR), gradient boost regressor (GBR), random forest regressor (RFR), and linear regressor (LR), showed significantly less mean absolute error and higher percentages of eyes within 50-200 µm of the targeted ICL vault than the conventional nomogram (P < .001). The RFR provided the lowest mean absolute errors and the highest percentages of eyes within 50 to 200 µm, followed by the GBR, the LR, and the SVR (P < .01).
Conclusions:
Machine learning of the preoperative anterior segment optical coherence tomography metrics, especially the RFR, provided significantly higher predictability of the ICL vault than the conventional manufacturer's nomogram, suggesting that it will become an aid for predicting the ICL vault and subsequently selecting the proper ICL size in daily practice.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
06:15Author Spotlight: Anterior HR-OCT as a Non-Invasive Tool for Characterizing Ocular Surface Squamous Neoplasia
Published on: August 9, 2024
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...