Related Experiment Video
Updated: Nov 17, 2025

Synthesis and Functionalization of 3D Nano-graphene Materials: Graphene Aerogels and Graphene Macro Assemblies
Published on: November 5, 2015
Evaluating humidity sensing response of graphene quantum dots synthesized by hydrothermal treatment of glucose
Nouman Khan1, Ahmad Nawaz2, Bilal Islam3
1Faculty of Engineering Sciences, Ghulam Ishaq Khan Institute of Engineering Sciences and Technology, Topi, 23640, KPK, Pakistan.
Abstract:
Graphene quantum dots (GQDs) were prepared using a single-step hydrothermal treatment of glucose (C6H12O6) powder. X-ray diffraction patterns confirmed the random stacking or amorphous character of GQDs. Additionally, the UV-vis spectra confirmed the formation of GQDs with evident absorption peaks at 237 and 305 nm, which is attributed toπ-π* andn-π* transitions correspondingly. The average size and surface roughness of graphene quantum dots were estimated by atomic force microscopy images and found to be 27.0 ± 1.0 and 2.3 nm, respectively. Afterwards, the effect of increasing relative humidity (RH) from 0%-95%, and frequency, was analyzed using the capacitive and resistive responses of synthesized GQDs. The capacitive output at 0.1 kHz revealed that initially capacitance remains constant (15.0 ± 1.0 pF) up to a humidity level ranging between 0%-50%. Likewise, capacitance also displayed stabilized behavior after frequency levels were increased i.e., 1.0 and 10 kHz, at a humidity ranging from 0%-55%. Moreover, capacitance showed a 115,455, 22,480 and 3,620% improvement from their stable values at each respective frequency level i.e., 0.1, 1.0 and 10 kHz. The capacitive sensitivity decreased to 84.20 and 96.83% at greater frequencies (1.0 and 10 kHz) in comparison to the sensitivity at 0.1 kHz facing similar variations in a humid environment. In contrast, resistance displayed an exponential decline by 99.9900, 99.9796 and 99.9925%, accordingly, when RH increases from 0 to 95% at 0.1, 1.0 and 10 kHz, respectively. However, with the rise in frequency level from 0.1 to 1.0 kHz, resistive sensitivity increased considerably to 69 and 158.5%, respectively, in two prominent humidity ranges i.e., 0 ≤ RH ≤ 25% and 25% ≤ RH ≤ 50%. A further increase in testing frequency to 10 kHz enhances the resistive sensitivity by 598.5 and 178.5% when compared with the lowest sensitivity values at two noticeable humidity levels, 0%-25% and 25%-50%. The response and recovery times of our specimen were better than most of previously fabricated GQDs and other carbon-derived nanomaterials, which makes the nano-GQDs of our study more suitable for RH sensor application.

