Stand out from matrix: Ultra-sensitive LC-MS/MS method for determination of histamine in complex biological samples
Xiaolan Hu1, Xiqing Bian1, Wan-Yi Gu1
1State Key Laboratory of Quality Research in Chinese Medicine, Macau University of Science and Technology, Avenida Wai Long, Taipa, Macau SAR, China.
This study presents a new ultra-sensitive method for measuring histamine in clinical samples. The technique accurately quantifies low histamine levels, crucial for diagnosing diseases like asthma and allergic reactions.
Area of Science:
- Biochemistry
- Analytical Chemistry
- Clinical Diagnostics
Background:
- Histamine is a key endogenous component involved in various physiological processes.
- Accurate histamine quantification is vital for diagnosing conditions such as allergies, asthma, and anaphylactic shock.
- Detecting low histamine concentrations in complex biological samples presents significant analytical challenges due to stability and matrix interference.
Purpose of the Study:
- To develop an ultra-sensitive and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for histamine quantification.
- To overcome the challenges associated with detecting low abundant histamine in clinical samples.
- To establish a reliable method for histamine determination in complex biological matrices.
Main Methods:
- Development of an LC-MS/MS method incorporating derivatization with diisopropyl phosphite (DIPP).
- Application of isotope dilution and solid-phase extraction (SPE) for enhanced sensitivity and interference removal.
- Optimization of derivatization to improve LC retention and ionization efficiency.
Main Results:
- Achieved an ultra-sensitive quantification method with a lowest limit of quantification (LLOQ) of 0.1 pg/mL.
- Demonstrated successful application in determining histamine in low nanoliter serum volumes and single cells.
- Validated the method by quantifying histamine in clinical serum samples from asthma patients and treated mast cells.
Conclusions:
- The developed LC-MS/MS method provides unprecedented sensitivity and accuracy for histamine determination.
- This approach enables the precise measurement of histamine in challenging clinical samples, aiding in disease diagnosis.
- The method is suitable for analyzing trace levels of histamine in various biological matrices, including serum and cellular samples.