Highly selective simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii) in water samples using
Pornphimon Kamnoet1, Wanlapa Aeungmaitrepirom1, Ruth F Menger2
1Environmental Analysis Research Unit (EARU), Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok 10330, Thailand. wanlapa.A@chula.ac.th.
Abstract:
A new paper-based analytical device design was fabricated by a wax printing method for simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii). Colorimetry was used to quantify these heavy metal ions using bathocuproine (Bc), dimethylglyoxime (DMG), dithizone (DTZ), and 4-(2-pyridylazo) resorcinol (PAR) as complexing agents. The affinity of complexing agents to heavy metal ions is dependent on the formation constant (Kf). To enhance the selectivity for heavy metal ion determination, the new device was designed with two pretreatment zones, where masking agents remove the interfering ions. It was found that two pretreatment zones worked better than a single pretreatment zone at removing interferences. The reaction time, sample and complexing agent volumes, and complexing agent concentrations were optimized. The analytical results were achieved with the lowest detectable concentrations of 0.32, 0.59, 5.87, 0.20, and 0.11 mg L-1 for Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii), respectively. The linear ranges were found to be 0.32-63.55 mg L-1 (Cu(ii)), 0.59-4.71 mg L-1 (Co(ii)), 5.87-352.16 mg L-1 (Ni(ii)), 0.20-12.04 mg L-1 (Hg(ii)), and 0.11-0.55 mg L-1 (Mn(ii)). The lowest detectable concentration and linearity for the five metal ions allow the application of this device for the determination of heavy metal ions in various water samples. The sensor showed high selectivity and efficiency for simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii) in drinking, tap, and pond water samples on a single device and detection with the naked eye. The results illustrated that the proposed sensor showed good accuracy and precision agreement with the standard ICP-OES method.
More Related Videos
05:35Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Precipitation and Co-precipitation
High-Performance Liquid Chromatography: Types of Detectors