Related Experiment Video
Updated: Nov 17, 2025

Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments
Published on: June 27, 2022
Dataset of measurements for the experimental CEA-beam benchmark structure subjected to one stochastic broadband
T Roncen1,2, J-P Lambelin1, Y Chantereau1
1CEA/CESTA, CS60001, 15 avenue des Salinières, 33116 Le Barp, France.
Abstract:
This data article comprises data to investigate the non-linear dynamic behavior of the CEA-beam benchmark structure subjected to one stochastic broadband excitation. Experiments have been performed on the CEA-CESTA laboratory. The data provided include the input Power Spectral Density for four levels of excitation and the associated output nonlinear dynamic behavior of the CEA-beam benchmark structure. All the results from this data will help researchers and engineers in proper analysis of hardening effect and the enlargement of the response peak due to one stochastic broadband excitation, as well as the presence of harmonics. One of the main original contributions is to share the data sets to give the opportunity to researchers for testing and validating analytical or numerical models of a nonlinear beam with non-ideal boundary conditions and subjected to one stochastic broadband excitation. This Data in Brief article is an additional item directly alongside the following paper published in the Communications in Nonlinear Science and Numerical Simulation (CNSNS) journal: T. Roncen, J-P. Lambelin and J-J. Sinou, Nonlinear vibrations of a beam with non-ideal boundary conditions and stochastic excitations - experiments, modeling and simulations, Communications in Nonlinear Science and Numerical Simulation,74 (2019) 14-29. doi.org/10.1016/j.cnsns.2019.03.006.
More Related Videos
08:44Measurements of Long-range Electronic Correlations During Femtosecond Diffraction Experiments Performed on Nanocrystals of Buckminsterfullerene
Published on: August 22, 2017
11:14Comprehensive Characterization of Extended Defects in Semiconductor Materials by a Scanning Electron Microscope
Published on: May 28, 2016
Related Concept Videos
Distribution of Stresses in a Narrow Rectangular Beam
Measurements of Strain
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...