Related Experiment Video
Updated: Nov 16, 2025

Analyzing Protein Architectures and Protein-Ligand Complexes by Integrative Structural Mass Spectrometry
Published on: October 15, 2018
Probing Folded Proteins and Intact Protein Complexes by Desorption Electrospray Ionization Mass Spectrometry
Bin Yan1, Josephine Bunch1,2,3
1National Centre of Excellence in Mass Spectrometry Imaging, National Physical Laboratory, Hampton Road, Teddington TW11 0LW, U.K.
Abstract:
Native mass spectrometry (MS) enables the study of intact proteins as well as noncovalent protein-protein and protein-ligand complexes in their biological state. In this work, we present the application of a Waters desorption electrospray ionization (DESI) source with a prototype spray emitter for rapid surface measurements of folded and native protein structures. A comparison of DESI spray solvent shows that adding 50% methanol to 200 mM ammonium acetate solution does not reduce its performance in preserving folded protein structures. Instead, improved signal-to-noise (S/N) ratio is obtained, and less adducted peaks are detected by using this uncommon native MS solvent system. The standard DESI design with an inlet tube allows optimization of sampling temperature conditions to improve desolvation and therefore S/N ratio. Furthermore, tuning the inlet temperature enables the control and study of unfolding behavior of proteins from surface samples. The optimized condition for native DESI has been applied to several selected proteins and protein complexes with the molecular weight ranging from 8.6 to 66.4 kDa. Ions of folded proteins with narrow charge state distribution (CSD), or peaks showing noncovalent-bond-assembled intact protein complexes, are observed in the spectra. Evidence for the structural refolding of denatured proteins and protein complexes sampled with native solvent highlights the need for care when interpreting DESI native MS data, particularly for proteins with stable native structures.
More Related Videos
10:01Combining Chemical Cross-linking and Mass Spectrometry of Intact Protein Complexes to Study the Architecture of Multi-subunit Protein Assemblies
Published on: November 28, 2017
07:49Matrix-assisted Laser Desorption/Ionization Time of Flight MALDI-TOF Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)