Related Experiment Video
Updated: Nov 16, 2025

Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Reliability of maximum oxygen uptake in cardiopulmonary exercise testing with continuous laryngoscopy
Mette Engan1,2,3, Ida Jansrud Hammer1,3, Marianne Bekken2
1Dept of Pediatric and Adolescent Medicine, Haukeland University Hospital, Bergen, Norway.
Aims:
A cardiopulmonary exercise test (CPET) is the gold standard to evaluate symptom-limiting exercise intolerance, while continuous laryngoscopy performed during exercise (CLE) is required to diagnose exercise-induced laryngeal obstruction. Combining CPET with CLE would save time and resources; however, the CPET data may be distorted by the extra equipment. We therefore aimed to study whether CPET with CLE influences peak oxygen uptake (V'O peak) and other gas exchange parameters when compared to a regular CPET.
Methods:
Forty healthy athletes without exercise-related breathing problems, 15-35 years of age, performed CPET to peak exercise with and without an added CLE set-up, in randomised order 2-4 days apart, applying an identical computerised treadmill protocol.
Results:
At peak exercise, the mean difference (95% confidence interval) between CPET with and without extra CLE set-up for V'O peak, respiratory exchange ratio (RER), minute ventilation (V'E) and heart rate (HR) was 0.2 (-0.4 to 0.8) mL·kg-1·min-1, 0.01(-0.007 to 0.027) units, 2.6 (-1.3 to 6.5) L·min-1 and 1.4 (-0.8 to 3.5) beats·min-1, respectively. Agreement (95% limits of agreement) for V'O peak, RER and V'E was 0.2 (±3.7) mL·kg-1·min-1, 0.01 (±0.10) units and 2.6 (±24.0) L·min-1, respectively. No systematic or proportional bias was found except for the completed distance, which was 49 m (95% CI 16 to 82 m) longer during CPET.
Conclusion:
Parameters of gas exchange, including V'O peak and RER, obtained from a maximal CPET performed with the extra CLE set-up can be used interchangeably with data obtained from standard CPET, thus preventing unnecessary additional testing.
More Related Videos
07:26Conducting Maximal and Submaximal Endurance Exercise Testing to Measure Physiological and Biological Responses to Acute Exercise in Humans
Published on: October 17, 2018
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...