Related Experiment Video
Updated: Nov 16, 2025

Measuring Pressure Volume Loops in the Mouse
Published on: May 2, 2016
Short-term exposure to noise on stroke volume and left ventricular contractility: A repeated-measure study
Ta-Yuan Chang1, Ya-Yun Wu1, Ven-Shing Wang1
1Department of Occupational Safety and Health, College of Public Health, China Medical University, Taiwan.
Abstract:
Prolonged exposure to noise has been associated with cardiovascular disease, but the possible mechanism for its influence on cardiac activity is unknown. This study investigated the acute effects of noise exposure on 24-h ambulatory cardiac parameters among male workers. We recruited 75 volunteers in an aviation-industry cohort in 2009. Personal noise-exposure levels and individual cardiac parameters, including stroke volume (SV) and left ventricular contractility (LVC), were measured simultaneously over 24 h on working and nonworking days. Linear mixed-effects regression models were used to estimate transient and sustained effects on ambulatory SV and LVC among high-noise-exposure (≥80 A-weighted decibels [dBA]), low-noise-exposure (<80 dBA) and office workers. Every 1-dBA increase in noise exposure was significantly associated with transient changes of -1.50 (95% confidence interval [CI]: -2.18, -1.03) ml/beat in SV and -1.76 (-2.99, -1.03) L/sec in LVC at work on working days only among high-exposure workers. The 1-dBA increase in nocturnal noise exposure was also significantly associated with transiently decreased SV among high-exposure (-1.62 [-2.15, -1.22] ml/beat), low-exposure (-1.27 [-1.57, -1.03] ml/beat) and office workers (-1.09 [-1.18, -1.00] ml/beat), but only the high-exposure group had the transiently reduced LVC (-1.70, [-2.37, -1.22] L/sec) after the current noise exposure on nonworking days. Such decreasing effects persisted to become sustained decreases in 24-h ambulatory SV in high-exposure (-1.10 [-1.20, -1.01] ml/beat) and office workers (-1.13 [-1.22, -1.05] ml/beat) on working days and in all three groups (-1.19 [-1.36, -1.04]; -1.15 [-1.31, -1.02]; -1.08 [-1.13, -1.02] ml/beat, respectively) on nonworking days. No significant effect on 24-h ambulatory LVC was found in any group on working or nonworking days. Occupational and nocturnal noise exposure may have acute effects on 24-h ambulatory SV among male workers, directly influencing the cardiac function related to cardiovascular disease.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
06:04Author Spotlight: Establishment and Confirmation of a Postnatal Right Ventricular Volume Overload Mouse Model
Published on: June 9, 2023
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...