Related Experiment Video
Updated: Nov 16, 2025

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Visual acuity, refractive error, and regression outcomes in 169 children with high myopia who were implanted with
Nicholas Faron1, James Hoekel1, Lawrence Tychsen2
1John F. Hardesty, MD, Department of Ophthalmology and Visual Sciences, Washington University in St. Louis School of Medicine, St. Louis, Missouri.
Purpose:
To analyze outcomes in a large cohort of spectacle-aversive children with high myopia who were treated by implantation of the Ophtec-Artisan or Visian phakic intraocular lens (pIOL).
Methods:
Outcome data were collated retrospectively in 78 children (115 eyes) implanted with the Ophtec-Artisan iris-enclaved anterior chamber pIOL and 91 children (154 eyes) implanted with the Visian ICL (intraocular collamer lens) sulcus pIOL. All children had difficulties with spectacle or contact lens wear. Mean age at surgery was 9.9 years; mean follow-up was 3.9 years (range, 0.6-14.1 years).
Results:
A total of 248 of 269 eyes (92%) were corrected to within ± 0.5 D of their target value. Spherical correction averaged 12.3 ± 1.0 D. Refractive spherical regression was -0.04 D/year at last follow-up. Uncorrected distance visual acuity improved from an average logMAR 1.8 to 0.4; corrected distance visual acuity improved an average 0.3 logMAR. Of the treated children, 68% had a gain in binocular fusion. Neurobehavioral and/or visuomotor comorbidities were present in 87% of children. Five eyes (2%) developed retinal detachment an average 6 years after implantation. Nine eyes (3%) implanted with the Ophtec-Artisan pIOL required repositioning after trauma.
Conclusions:
Implantation of pIOLs in children is an effective method for correcting high myopia in spectacle noncompliant children. Rates of myopic regression after pIOL surgery are substantially lower than those reported for children treated by excimer laser photorefractive keratectomy (PRK). The prevalence of major complications was relatively low in this high-risk population.
Related Concept Videos
Focusing of Light in the Eye
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Glaucoma: Overview
Photoreceptors and Visual Pathways