Related Experiment Video
Updated: Nov 16, 2025

Infrared Thermography for the Detection of Changes in Brown Adipose Tissue Activity
Published on: September 28, 2022
The use of infrared thermal imaging in tonometry with a Scheimpflug camera
Magdalena Jędzierowska1, Robert Koprowski1, Sławomir Wilczyński2
1Institute of Biomedical Engineering, Faculty of Science and Technology, University of Silesia in Katowice, ul. Będzińska 39, Sosnowiec 41-200, Poland.
Abstract:
Infrared thermal imaging is currently used in almost every field of medicine. This paper presents the novel use of thermography in ophthalmology - using a thermal camera to assess correct intraocular pressure measurement depending on the position of the patient's head during non-contact tonometry. For the analysed group of 10 healthy subjects, thermographic images of the face were recorded before and after intraocular pressure testing. Pressure was tested with a non-contact tonometer with a Scheimpflug camera. For the acquired 20: 2D images (thermograms), an analysis of the characteristic areas of the face determined temperature changes of the patient's face in contact with the tonometer frame. Analysis and processing of the acquired thermograms was carried out in MATLAB® with the Image Processing Toolbox. The results clearly showed a decrease in the patient's face temperature where the face was in contact with tonometer supports. Temperature changes in the patient's face provide valuable information about the correct position of their head in the device, which directly translates into measurement quality. Therefore, the analysis of changes in the patient's face temperature both before and after the examination can be a tool for assessing correct patient positioning in the tonometer supports.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...