Propensity score-based analysis of long-term outcome of patients on HeartWare and HeartMate 3 left ventricular assist
Lieke Numan1, Faiz Z Ramjankhan2, Daniel L Oberski3
1Department of Cardiology, University Medical Centre Utrecht, Utrecht University, Heidelberglaan 100, Utrecht, 3584 CX, The Netherlands.
Insights
HeartMate 3 (HM3) and HeartWare (HVAD) left ventricular assist devices show similar long-term survival. However, HM3 demonstrated significantly lower rates of hemorrhagic stroke and pump thrombosis compared to HVAD in this single-center study.
Area of Science:
- Cardiovascular Medicine
- Medical Devices
- Heart Failure Treatment
Background:
- Left ventricular assist device (LVAD) therapy is crucial for end-stage heart failure, used for destination therapy, bridge to transplant, or recovery.
- HeartMate 3 (HM3) and HeartWare (HVAD) are leading centrifugal continuous flow LVADs, but direct comparative outcome data is limited.
- Registry analyses are challenged by center-specific standards of care and potential biases due to non-random device selection.
Purpose of the Study:
- To compare the long-term clinical outcomes of patients receiving HeartMate 3 (HM3) versus HeartWare (HVAD) left ventricular assist devices.
- To address limitations of registry data by performing a propensity score-based analysis within a single center.
- To evaluate differences in survival, stroke, pump thrombosis, and other adverse events between HM3 and HVAD recipients.
Main Methods:
- A propensity score (PS) matching analysis was conducted on 181 patients (81 HM3, 100 HVAD) implanted between December 2010 and December 2019.
- Extensive covariates were used for PS matching, resulting in 112 matched patients with a median follow-up of 28 months.
- Survival and cumulative incidences of adverse events (hemorrhagic stroke, pump thrombosis, major bleeding, ischemic stroke, right heart failure, driveline infection) were compared.
Main Results:
- After PS matching, survival was not significantly different (P=0.21) but trended better for HM3.
- HVAD recipients had significantly higher cumulative incidences of hemorrhagic stroke (P=0.01) and pump thrombosis (P=0.02).
- No significant differences were observed in major bleeding, ischemic stroke, right heart failure, or driveline infection between the groups.
Conclusions:
- While overall survival was similar, the HM3 device was associated with a significantly lower incidence of hemorrhagic stroke and pump thrombosis compared to HVAD.
- Propensity score matching helps mitigate bias, but unmeasured confounders may still influence outcomes.
- A multicenter study with carefully selected centers is recommended to increase sample size and enhance the robustness of comparative LVAD outcome analyses.
Aims:
Left ventricular assist device therapy has become the cornerstone in the treatment of end-stage heart failure and is increasingly used as destination therapy next to bridge to transplant or recovery. HeartMate 3 (HM3) and HeartWare (HVAD) are centrifugal continuous flow devices implanted intrapericardially and most commonly used worldwide. No randomized controlled trials have been performed yet. Analysis based on large registries may be considered as the best alternative but has the disadvantage of different standard of care between centres and missing data. Bias is introduced, because the decision which device to use was not random, even more so because many centres use only one type of left ventricular assist device. Therefore, we performed a propensity score (PS)-based analysis of long-term clinical outcome of patients that received HM3 or HVAD in a single centre.
Methods And Results:
Between December 2010 and December 2019, 100 patients received HVAD and 81 patients HM3 as primary implantation at the University Medical Centre Utrecht. We performed PS matching with an extensive set of covariates, resulting in 112 matched patients with a median follow-up of 28 months. After PS matching, survival was not significantly different (P = 0.21) but was better for HM3. The cumulative incidences for haemorrhagic stroke (P = 0.01) and pump thrombosis (P = 0.02) were significantly higher for HVAD patients. The cumulative incidences for major bleeding, ischaemic stroke, right heart failure, and driveline infection were not different between the groups. We found no interaction between the surgeon who performed the implantation and survival (P = 0.59, P = 0.78, and P = 0.89). Sensitivity analysis was performed, by PS matching without patients on preoperative temporary support resulting in 74 matched patients. This also resulted in a non-significant difference in survival (P = 0.07). The PS-adjusted Cox regression showed a worse but non-significant (P = 0.10) survival for HVAD patients with hazard ratio 1.71 (95% confidence interval 0.91-3.24).
Conclusions:
Survival was not significantly different between both groups after PS matching, but was better for HM3, with a significantly lower incidence of haemorrhagic stroke and pump thrombosis for HM3. These results need to be interpreted carefully, because matching may have introduced greater imbalance on unmeasured covariates. A multicentre approach of carefully selected centres is recommended to enlarge the number of matched patients.
More Related Videos
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Heart Failure V: Medical Management