Research on detection scheme of pebbles in fuel handling system pipelines in pebble-bed HTGR based on γ-ray
Shiming Yin1, Liguo Zhang1, Haitao Wang1
1Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Key Laboratory of Advanced Reactor Engineering and Safety, Ministry of Education, Tsinghua University, Beijing, 100084, People's Republic of China.
Abstract:
In the pebble-bed high temperature gas-cooled reactor (HTGR), the fresh fuel pebbles and the graphite pebbles are loaded before reaching the stable stage. After several circulations, the spent fuel needs to be dispensed into the corresponding containers. During the circulations, we need to count the passing of pebbles, distinguish and count the discharged spent pebbles to meet the requirements by nuclear safeguarding. Therefore, along the pipelines, detectors with these certain functions are required. In this paper, by using the characteristics of pebbles' different γ radiation intensities, we design the schemes to use scintillator detectors to carry out the detection. Based on the above principle, the detection process is simulated and evaluated. Through the MCNP simulation, we estimate the relevant signals of four different pebbles -- fresh graphite pebbles and fresh fuel pebbles, irradiated graphite pebbles and spent fuel pebbles -- when they pass through the detector, to demonstrate the feasibility of the detection scheme to identify and count these pebbles.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
