Related Experiment Video
Updated: Nov 16, 2025

Treating Surfaces with a Cold Atmospheric Pressure Plasma using the COST-Jet
Published on: November 2, 2020
Inactivation of norovirus by atmospheric pressure plasma jet on salmon sashimi
Yi-Ming Huang1, Wei-Chih Chang2, Chuan-Liang Hsu2
1Department of Chemical and Materials Engineering, National Chin-Yi University of Technology, Taichung 41170, Taiwan.
Abstract:
This study investigated atmospheric pressure plasma (APP) jet, an emerging novel non-thermal technology, for the inactivation of human norovirus (NoV) on salmon sashimi. The influences of the non-thermal plasma on quality attributes of sashimi were also evaluated. Air, O2, and N2 (15 L/min) were used to produce the plasma jets. N2 plasma treatment for 12 min reduced NoV viral load (VL) (initial inoculums of 2.7 × 104 copies/g) by 2.17 × 104 copies/g, while air-based or O2-based plasma treatment for 9-12 min could reduce the VL to undetectable levels (below 100 copies/g). Under the same operating condition, the air-based or O2-based plasma treatment might increase slightly TBARS values in sashimi, yet the values (far below 1.0 mg MDA/kg) were within acceptable level for sashimi made with salmon fishes. The APP jets (APPJ) treatments could also retain the pH of sashimi at normal levels (6.29 ~ 6.02) to maintain the quality of salmon sashimi, the color quality of which was not affected evidently. The plasma-induced hardness and springiness changes in salmon sashimi were substantially low. These results suggested APPJ could be implemented as technology for inactivation of food-borne viruses and exhibited a high potential for application in fish sashimi processing, retaining product quality as well.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...