Wind Effects on a Tall Building with Square Cross-Section and Mid-Side Base Columns: Database-Assisted Design
Sejun Park1, Dat Duthinh2, Emil Simiu3
1NIST Director's Postdoctoral Research Associate, Engineering Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899.
Database-assisted design (DAD) for high-rise buildings shows corner winds impose lower structural demands than face winds. This study on square-plan buildings suggests re-evaluating historical designs like the Citicorp Building.
Area of Science:
- Structural Engineering
- Wind Engineering
- Computational Mechanics
Background:
- High-rise buildings require robust wind-resistant designs.
- Database-Assisted Design (DAD) offers a systematic approach to structural analysis.
- Understanding wind load effects on square-plan structures is crucial for safety and efficiency.
Purpose of the Study:
- To apply the Database-Assisted Design (DAD) method to the wind design of high-rise buildings.
- To compare structural responses of a square-plan building subjected to corner winds versus face winds.
- To evaluate the implications for historical building codes and designs, such as the Citicorp Building.
Main Methods:
- Utilized publicly available wind tunnel data and DAD procedures.
- Analyzed structural dynamics and second-order load-deformation effects.
- Compared overturning moments and demand-to-capacity indexes (DCIs) for critical structural members.
Main Results:
- Corner winds resulted in approximately 20% lower along-wind and 50% lower across-wind overturning moments compared to face winds.
- Peak axial forces in legs and DCIs in mid-side mast columns were 20%-30% lower under corner winds.
- The study confirmed a potential interpretation of 1970s NYC building codes allowing face-wind design assumptions for square structures.
Conclusions:
- Corner winds are less demanding than face winds for square-plan high-rise buildings.
- The findings suggest that historical wind design practices might have underestimated the benefits of considering corner wind effects.
- A re-examination of the design and retrofit history of structures like the Citicorp Building may be warranted based on these results.
Related Concept Videos
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Design of Columns under an Eccentric Load
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Design of Prismatic Beams for Bending
Euler's Formula to Columns with Other End Conditions
Design Example: Dimensioning of Concrete Masonry Construction
The site engineer has laid out a plan for the storeroom with external dimensions of twelve feet in length and...