Related Experiment Video
Updated: Nov 15, 2025

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Difference of refractive status before and after cycloplegic refraction: the Lhasa Childhood Eye Study
Lei Li1, Jing Fu2, Weiwei Chen1,3
1Strabismus and Pediatric Ophthalmology, Beijing Ophthalmology and Visual Sciences Key Laboratory Ophthalmology Department of Beijing Tongren Hospital, Beijing Tongren Eye Center, Capital Medical University, No.1, Dong Jiao Min Xiang Street, Dongcheng District, Beijing, 100730, People's Republic of China.
Purpose:
To compare the differences between cycloplegic and noncycloplegic refraction as well as associated factors in grade one students of primary schools, and explore the effectiveness of noncycloplegic refraction for refractive error screening.
Study Design:
Cross-sectional study.
Methods:
A school-based study of 1856 students was conducted in Lhasa, Tibetan Plateau, China. Cycloplegia was achieved with two drops of 1% cyclopentolate and 1 drop of Mydrin P at a 5-min interval. Autorefraction was performed under both cycloplegic and noncycloplegic conditions. Bland-Altman analysis, receiver operating characteristic curve analysis, univariate and multiple linear regression models were used for analysis.
Results:
Of the 1856 children enrolled, 1830 (98.60%) completed all procedures. The average age was 6.83 ± 0.46 years. 965 (52.73%) children were boys and 1737 (94.92%) were Tibetan. Overall, there was a significant difference between cycloplegic and noncycloplegic SE of 0.90 ± 0.76D (P < 0.001). However, the intra-class coefficient correlation (ICC) for cylinder between these two methods was high (ICC = 0.941, 95% CI, 0.935-0.946). Larger differences between cycloplegic and noncycloplegic SE were associated with hyperopic RE and higher cylindrical value (P < 0.001). The prevalence of myopia, emmetropia and hyperopia with and without cycloplegia was (3.93% vs 14.59%), (9.95% vs 45.8%) and (86.21% vs 39.56%), respectively. Myopia, emmetropia and hyperopia based on noncycloplegic refraction was defined as SE ≤ - 0.625D, - 0.625 < SE ≤ 0D, and SE > 0D, respectively.
Conclusions:
Lack of cycloplegia leads to underestimation of hyperopia, with overestimation of myopia and emmetropia. Larger hyperopic refraction exhibited greater difference between cycloplegic and noncycloplegic refraction.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024