Related Experiment Video
Updated: Nov 15, 2025

Establishing a Silicosis Rat Model via Exposure of Whole-Body to Respirable Silica
Published on: October 28, 2022
Evaluation of differential serum expression of three factors and pulmonary function in patients with silicosis
Ying Zhu1, Xia Yu Duan1, Yun Qi Cheng1
1North China University of Science and Technology, Tangshan, China (School of Public Health).
Objectives:
Silicosis is a chronic occupational lung disease. As was previously found by the authors, some proteins increased in the lung tissue of activated rats, and protein tyrosine phosphatase non-receptor type 2 (PTPN2), factor B, and vaccinia-related kinase 1 (VRK1) showed highly differential expressions.
Material And Methods:
In this study, serum and bronchoalveolar lavage fluid samples were collected from patients with silicosis and healthy people to verify the expression of PTPN2, factor B, and VRK1. The diagnostic value of differentially expressed proteins for silicosis was judged.
Results:
The expression levels of serum PTPN2, VRK1, and factor B in patients with silicosis were significantly higher than those in the control group (p < 0.01). Higher serum PTPN2 and factor B concentrations significantly and negatively correlated with the ratio of forced expiratory volume in 1 s to forced vital capacity (FEV1/FVC), maximum vital capacity (VCmax), FEV1, and FVC, suggesting that the high expression of PTPN2 and factor B is associated with decreased pulmonary ventilation function and restrictive ventilatory impairment in patients with silicosis. All area under curve (AUC) measurements generated from single detection events were >0.744, with PTPN2 reaching the highest value (0.858). The AUC, sensitivity, and specificity for the combined diagnosis using factor B and PTPN2 were 0.907, 86.91% and 85.07%, respectively, for factor B and PTPN2. The 3 differentially expressed proteins are potential classes of predictive biomarkers for silicosis.
Conclusions:
Regarding the economy and test practicality, the best diagnostic combination is factor B and PTPN2 for the analysis of AUC, sensitivity and specificity. Int J Occup Med Environ Health. 2021;34(4):527-40.
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Pneumonia III: Complications and Assessment
Pulmonary Tuberculosis IV
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...