Related Experiment Video
Updated: Nov 15, 2025

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Numerical Analysis of a Continuous Vulcanization Line to Enhance CH4 Reduction in XLPE-Insulated Cables
Mohd Fuad Anwari Che Ruslan1, Dong Joon Youn1, Roshan Aarons2
1Computational Transport Phenomena Lab, King Abdullah University of Science and Technology, Thuwal 23955-6900, Saudi Arabia.
Abstract:
Herein, we apply a computational diffusion model based on Fick's law to study the manner in which a cable production line and its operating conditions can be enhanced to effectively reduce the CH4 concentration in cables insulated with cross-linked polyethylene (XLPE). Thus, we quantitatively analyze the effect of the conductor temperature, curing tube temperature distribution, transition zone length, and online relaxation on CH4 generation and transport during the production of 132 kV cables with an insulation thickness of 16.3 mm. Results show that the conductor temperature, which is initially controlled by a preheater, and the curing tube temperature distribution considerably affect the CH4 concentration in the cable because of their direct impact on the insulation temperature. The simulation results show 2.7% less CH4 remaining in the cable when the preheater is set at 160 °C compared with that when no preheater is used. To study the curing tube temperature distribution, we consider three distribution patterns across the curing tube: constant temperature and linear incremental and decremental temperature. The amount of CH4 remaining in the cable when the temperature was linearly increased from 300 to 400 °C was 1.6% and 3.7% lower than in the cases with a constant temperature at 350 °C and a linear temperature decrease from 400 to 300 °C, respectively. In addition, simulations demonstrate that the amount of CH4 removal from the cable can be increased up to 9.7% by applying an elongated and insulated transition zone, which extends the residence time for CH4 removal and decelerates the decrease in cable temperature. Finally, simulations show that the addition of the online relaxation section can reduce the CH4 concentration in the cable because the high cable temperature in this section facilitates CH4 removal up to 2.2%, and this effect becomes greater at low production speeds.
Related Concept Videos
Cable Subjected to Concentrated Loads
Cable Subjected to a Distributed Load
Transmission-Line Differential Equations
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured from...
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Cable: Problem Solving