Related Experiment Video
Updated: Nov 15, 2025

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Zygomatic implant penetration to the central portion of orbit: a case report
Luan Mavriqi1, Felice Lorusso2, Roberto Conte3
1University of Albania University, Tirana, Albania.
Background:
Zygomatic implants have been proposed in literature for atrophic maxillary fixed oral rehabilitations. The aim of the present research was to evaluate, by a clinical and tomography assessment, a surgical complication of a zygomatic implant penetration to the orbit.
Case Presentation:
A 56 year-old female patient was visited for pain and swelling in the left orbit after a zygomatic implant protocol. The orbit invasion of the zygomatic implant screw was confirmed by the CBCT scan. The patient was treated for surgical implant removal and the peri- and post-operative symptoms were assessed. No neurological complications were reported at the follow-up. The ocular motility and the visual acuity were well maintained. No purulent secretion or inflammatory evidence were reported in the post-operative healing phases.
Conclusion:
The penetration of the orbit during a zygomatic implant positioning is a surgical complication that could compromise the sight and movements of the eye. In the present case report, a zygomatic implant removal resulted in an uneventful healing phase with recovery of the eye functions.