Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
Maciej S Wróbel1, Jeong Hee Kim2, Piyush Raj2
1Department of Metrology and Optoelectronics, Faculty of Electronics, Telecommunications, and Informatics, Gdańsk University of Technology, G. Narutowicza 11/12, 80-233, Gdańsk, Poland.
Abstract:
Non-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific variations in tissue properties introduce significant variability of the spectra, thereby preventing reliable calibration. For measurements of blood analytes such as glucose, we propose to decrease the interference from individual tissue characteristics by exploiting the known dynamics of the blood-tissue matrix. We reason that by leveraging the natural blood pulse rhythm, the signals from the blood analytes can be enhanced while those from the static components can be effectively suppressed. Here, time-resolved measurements with subsequent pulse frequency estimation and phase-sensitive detection are proposed to recover the Raman spectra correlated with the dynamic changes at blood-pulse frequency. Pilot in vivo study results are presented to establish the benefits as well as outline the challenges of the proposed method in terms of instrumentation and signal processing.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...