Preventing Inadvertent Foreign Body Injection in Angiography
Omid Nikoubashman1, Afif Kraitem1, Rose Arslanian1
1From the Department of Neuroradiology, University Hospital RWTH Aachen, Neuroradiologie, Universitätsklinikum Aachen, Pauwelsstr 30, 52074 Aachen, Germany (O.N., T.S., M.W.); and New England Center for Stroke Research, University of Massachusetts Medical School, Worcester, Mass (A.K., R.A., M.J.G.).
Abstract:
Background Inadvertent injection of foreign material during angiography, particularly neuroangiography, should be avoided to reduce the risk of embolic complications. Woven gauze and cotton fabrics have been identified as sources of inadvertent foreign body embolization. Purpose To find the source of particles that contaminate injections on an angiography table and to identify measures for their reduction. Materials and Methods The number and size of particles on an angiographic supply table at a tertiary stroke center were analyzed by using the Coulter principle in September 2019. Seven conditions (saline directly drawn from its bag, from a small metal cup, from a small plastic cup, from a large plastic bowl, from a large plastic bowl with a guidewire and its sheath, from a large plastic bowl with a stack of woven gauze, and from a large plastic bowl with a large cotton towel) were tested at different time intervals (0, 30, and 60 minutes). Each container was filled with saline, and particle count was analyzed immediately after unpackaging, after rinsing with saline, and after introduction of foreign material; t tests were used for statistical comparisons. Results Freshly unpacked basins can be contaminated with many submillimetric particles (range, 4.4-25.1 particles per milliliter on average, depending on basin). Cotton towels and woven gauze placed in rinsed basins resulted in a significant increase in particles (from 1.5 particles per milliliter ± 0.4 [standard deviation] to 64.4 particles per milliliter ± 4.1 and 257.1 particles per milliliter ± 11.6, respectively; P < .001). Rinsing basins with saline significantly reduced the number of particles (P ≤ .03). Drawing saline directly from bags through intravenous lines yielded the lowest number of particles (0.1 particles per milliliter). Conclusion To decrease the risk for foreign body embolization, it is best to rinse all basins before use, draw saline and contrast agents directly from the respective bags and bottles through intravenous lines, and avoid cotton towels and woven gauze in basins and on the angiography table altogether whenever possible. © RSNA, 2021 See also the editorial by Nikolic in this issue.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Prevention of Further Absorption of Poison
Imaging Studies VII: Vascular Imaging
Cardiac Catheterization I: Pre-Procedure Overview